@@ -43,18 +43,18 @@ The following tables list the accuracy and precision specifications for Opentron
4343
Flex 1-channel pipettes meet the following accuracy and precision specifications.
4444

4545
<table>
46-
<thead>
47-
<tr>
48-
<th>Pipette Type</th>
49-
<th>Tip Size</th>
50-
<th>Volume (µL)</th>
51-
<th>Random Error (% CV)</th>
52-
<th>Systematic Error (% D)</th>
53-
</tr>
54-
</thead>
46+
<thead>
47+
<tr>
48+
<th>Pipette Type</th>
49+
<th>Tip Size</th>
50+
<th>Volume (µL)</th>
51+
<th>Random Error<br>(%&nbsp;CV)</th>
52+
<th>Systematic Error<br>(%&nbsp;D)</th>
53+
</tr>
54+
</thead>
5555
<tbody>
5656
<tr>
57-
<td rowspan="5"><b>1-Channel (1–50 µL)</b></td>
57+
<td rowspan="5"><b>1–50 µL</b></td>
5858
<td>20 µL</td>
5959
<td>1</td>
6060
<td>3.50%</td>
@@ -85,7 +85,7 @@ Flex 1-channel pipettes meet the following accuracy and precision specifications
8585
<td>±1.25%</td>
8686
</tr>
8787
<tr>
88-
<td rowspan="4"><b>1-Channel (5–1000 µL)</b></td>
88+
<td rowspan="4"><b>5–1000 µL</b></td>
8989
<td>50 µL</td>
9090
<td>5</td>
9191
<td>2.50%</td>
@@ -117,59 +117,71 @@ Flex 1-channel pipettes meet the following accuracy and precision specifications
117117
Flex 8-channel pipettes meet the following accuracy and precision specifications.
118118

119119
<table>
120-
<thead>
120+
<thead>
121+
<tr>
122+
<th>Pipette Type</th>
123+
<th>Tip Size</th>
124+
<th>Volume (µL)</th>
125+
<th>Random Error<br>(%&nbsp;CV)</th>
126+
<th>Systematic Error<br>(%&nbsp;D)</th>
127+
</tr>
128+
</thead>
129+
<tbody>
121130
<tr>
122-
<th>Pipette Capacity</th>
123-
<th>Tip Capacity</th>
124-
<th>Tested Volume</th>
125-
<th>Accuracy %D</th>
126-
<th>Precision %CV</th>
131+
<td rowspan="5"><b>1–50 µL</b></td>
132+
<td>20 µL</td>
133+
<td>1</td>
134+
<td>6.00%</td>
135+
<td>±10.00%</td>
127136
</tr>
128-
</thead>
129-
<tbody>
130137
<tr>
131-
<td rowspan="3"><b>1–50 µL</b></td>
132138
<td>50 µL</td>
133-
<td>1 µL</td>
134-
<td>±10.00%</td>
139+
<td>1</td>
135140
<td>8.00%</td>
141+
<td>±10.00%</td>
136142
</tr>
137143
<tr>
138-
<td>50 µL</td>
139-
<td>10 µL</td>
140-
<td>±2.50%</td>
144+
<td>20 µL</td>
145+
<td>5</td>
141146
<td>1.00%</td>
147+
<td>±2.50%</td>
142148
</tr>
143149
<tr>
144150
<td>50 µL</td>
151+
<td>10</td>
152+
<td>1.00%</td>
153+
<td>±2.50%</td>
154+
</tr>
155+
<tr>
145156
<td>50 µL</td>
146-
<td>±1.25%</td>
157+
<td>50</td>
147158
<td>0.60%</td>
159+
<td>±1.25%</td>
148160
</tr>
149161
<tr>
150162
<td rowspan="4"><b>5–1000 µL</b></td>
151163
<td>50 µL</td>
152-
<td>5 µL</td>
164+
<td>5</td>
165+
<td>4.00%</td>
153166
<td>±8.00%</td>
154-
<td>4%</td>
155167
</tr>
156168
<tr>
157169
<td>50 µL</td>
158-
<td>50 µL</td>
159-
<td>±2.50%</td>
170+
<td>50</td>
160171
<td>0.60%</td>
172+
<td>±2.50%</td>
161173
</tr>
162174
<tr>
163175
<td>200 µL</td>
164-
<td>200 µL</td>
165-
<td>±1.00%</td>
176+
<td>200</td>
166177
<td>0.25%</td>
178+
<td>±1.00%</td>
167179
</tr>
168180
<tr>
169181
<td>1000 µL</td>
170-
<td>1000 µL</td>
171-
<td>±0.70%</td>
182+
<td>1000</td>
172183
<td>0.15%</td>
184+
<td>±0.70%</td>
173185
</tr>
174186
</tbody>
175187
</table>
@@ -179,66 +191,73 @@ Flex 8-channel pipettes meet the following accuracy and precision specifications
179191
Flex 96-channel pipettes meet the following accuracy and precision specifications.
180192

181193
<table>
182-
<thead>
194+
<thead>
195+
<tr>
196+
<th>Pipette Type</th>
197+
<th>Tip Size</th>
198+
<th>Volume (µL)</th>
199+
<th>Random Error<br>(%&nbsp;CV)</th>
200+
<th>Systematic Error<br>(%&nbsp;D)</th>
201+
</tr>
202+
</thead>
203+
<tbody>
183204
<tr>
184-
<th>Pipette Capacity</th>
185-
<th>Tip Capacity</th>
186-
<th>Tested Volume</th>
187-
<th>Accuracy %D</th>
188-
<th>Precision %CV</th>
205+
<td rowspan="5"><b>1–200 µL</b></td>
206+
<td>20 µL</td>
207+
<td>1</td>
208+
<td>3.00%</td>
209+
<td>±10.00%</td>
189210
</tr>
190-
</thead>
191-
<tbody>
192211
<tr>
193-
<td rowspan="4"><b>1–200 µL</b></td>
194212
<td>50 µL</td>
195-
<td>1 µL</td>
196-
<td>±10%</td>
197-
<td>6%</td>
213+
<td>1</td>
214+
<td>6.00%</td>
215+
<td>±10.00%</td>
198216
</tr>
199217
<tr>
200-
<td>50 µL</td>
201-
<td>5 µL</td>
202-
<td>±4%</td>
203-
<td>2%</td>
218+
<td>20 µL</td>
219+
<td>5</td>
220+
<td>1.00%</td>
221+
<td>±4.00%</td>
204222
</tr>
205223
<tr>
206224
<td>50 µL</td>
207-
<td>50 µL</td>
208-
<td>±1.5%</td>
209-
<td>1%</td>
225+
<td>50</td>
226+
<td>1.00%</td>
227+
<td>±1.50%</td>
210228
</tr>
211229
<tr>
212230
<td>200 µL</td>
213-
<td>200 µL</td>
214-
<td>±1%</td>
215-
<td>1%</td>
231+
<td>200</td>
232+
<td>1.00%</td>
233+
<td>±1.00%</td>
216234
</tr>
217235
<tr>
218236
<td rowspan="4"><b>5–1000 µL</b></td>
219237
<td>50 µL</td>
220-
<td>5 µL</td>
221-
<td>±10%</td>
222-
<td>5%</td>
238+
<td>5</td>
239+
<td>5.00%</td>
240+
<td>±10.00%</td>
223241
</tr>
224242
<tr>
225243
<td>50 µL</td>
226-
<td>50 µL</td>
227-
<td>±2.5%</td>
244+
<td>50</td>
228245
<td>1.25%</td>
246+
<td>±2.50%</td>
229247
</tr>
230248
<tr>
231249
<td>200 µL</td>
232-
<td>200 µL</td>
233-
<td>±1.5%</td>
250+
<td>200</td>
234251
<td>1.25%</td>
252+
<td>±1.50%</td>
235253
</tr>
236254
<tr>
237255
<td>1000 µL</td>
238-
<td>1000 µL</td>
239-
<td>±1.5%</td>
240-
<td>1.5%</td>
256+
<td>1000</td>
257+
<td>1.50%</td>
258+
<td>±1.50%</td>
241259
</tr>
260+
</tbody>
242261
</table>
243262

244263
## Pipette calibration

0 commit comments

Comments
 (0)